Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input | ||||
Input signals | Current | Voltage | Resistance | Thermocouple |
Input Impedance | ≤250Ω | ≥500KΩ | ||
Maximum input current | ≤30mA | |||
Maximum input voltage |
≤6V | |||
Output | ||||
Output signals | Current | Voltage | Relay | 24V Distribution or feeder |
Output load capability | ≤500Ω | ≥250 KΩ (Note: Please replace the module for higher load capacity) |
AC220V/0.6(small) DC24V/0.6A(small) AC220V/3A(big) DC24V/3A(big) According to Remarks |
≤30mA |
Comprehensive parameter | ||||
Accuracy | 0.2%FS±1word | |||
Setting model | Panel touch key parameter setting values locking; store the setting values permanently |
|||
Display style | -1999 ~ 9999 display range 0 ~ 100% measured value lightness bargraph display; LED display for working state |
|||
Working environment | Ambient temperature: 0 ~ 50 ºC; Relative humidity: ≤ 85% RH; Far from strong corrosive gas |
|||
Power supply | AC 100 ~ 240V, (50/60HZ); DC 20 ~ 29V |
|||
Power | ≤5W | |||
Frame | Standard snap on | |||
Communication | Standard MODBUS communication protocol, RS-485, communication distance up to 1 km, RS-232, communication distance up to 15 meters Note: While with a communication function, the communication converter should be a active one. |
1. Specification | 2. Graduation Input | ||
Code | Width*Height*Depth | Code | Graduation (Measuring Range) |
A | 160*80*110mm (Horizontal type) | 0 | Thermocouple B(400~1800ºC) |
B | 80*160*110mm (Vertical Type) | 1 | Thermocouple S(0~1600ºC) |
C | 96*96*110mm (Quadrate Type) | 2 | Thermocouple K(0~1300ºC) |
D | 96*48*110mm (Horizontal type) | 3 | Thermocouple E(0~1000ºC) |
E | 48*96*110mm (Vertical Type) | 4 | Thermocouple T(-200.0~400.0ºC) |
F | 72*72*110mm (Quadrate Type) | 5 | Thermocouple J(0~1200ºC) |
H | 48*48*110mm (Quadrate Type) | 6 | Thermocouple R(0~1600ºC) |
3. OUTPUT | 7 | Thermocouple N(0~1300ºC) | |
Code | Output Type ( load resistance RL) | 8 | F2(700~2000ºC) |
X | No output | 9 | Thermocouple Wre3-25(0~2300ºC) |
0 | 4-20mA(RL≤500Ω) | 10 | Thermocouple Wre5-26(0~2300ºC) |
1 | 1-5V(RL≥250KΩ) | 11 | Thermal Resistance CU50(-50.0~150.0ºC) |
2 | 0-10mA(RL≤1KΩ) | 12 | Thermal Resistance CU53(-50.0~150.0ºC) |
3 | 0-5V(RL≥250KΩ) | 13 | Thermal Resistance CU100(-50.0~150.0ºC) |
4 | 0-20mA(RL≤500Ω) | 14 | Thermal Resistance PT100(-200.0~650.0ºC) |
5 | 0-10V(RL≥4KΩ) | 15 | Thermal Resistance BA1(-200.0.0~600.0ºC) |
D1 | RS485 communication interface (Modbus RTU) | 16 | Thermal Resistance BA2(-200.0~600.0ºC) |
4. Alarm (Relay contact output)(See Note) | 17 | Linear Resistance 0~1KΩ(-1999~9999) | |
Code | Alarm Ways | 18 | Remote Resistance 0-350Ω (-1999~9999) |
X | No Output | 19 | Remote Resistance 30-350Ω (-1999~9999) |
1 | 1 way Alarm | 20 | 0~20mV (-1999~9999) |
2 | 2 way Alarm | 21 | 0~40mV (-1999~9999) |
5. Power Output | 22 | 0~100mV (-1999~9999) | |
Code | Power Output (Output Voltage) | 23 | Internal retention |
X | No output | 24 | Internal retention |
P | Power Output(Load Current≤30mA) | 25 | 0~20mA (-1999~9999) |
Such as "P(24)"says Power Output24V. | 26 | 0~10mA (-1999~9999) | |
6.Power Supply | 27 | 4~20mA (-1999~9999) | |
Code | Voltage Range | 28 | 0~5V (-1999~9999) |
A | AC/DC 100-240V (AC/50-60Hz) | 29 | 1~5V (-1999~9999) |
D | DC 12-36V | 30 | Internal retention |
7. Remark | 31 | 0~10V (-1999~9999) | |
No remarks can be omitted | 32 | 0~10mA Square Root (-1999~9999) | |
33 | 4~20mA Square Root (-1999~9999) | ||
34 | 0~5V Square Root (-1999~9999) | ||
35 | 1~5V Square Root (-1999~9999) | ||
55 | All Switch |